Afrikaans
English Chinese Simplified Chinese Traditional French German Portuguese Spanish Russian Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Inquiry
Form loading...
HS78-600A/900A-C Stroomsensor
Ooplus-sensor (EV)

HS78-600A/900A-C Stroomsensor

Funksie beskrywing:

Die primêre en sekondêre kante van hierdie reeks sensors is geïsoleer vir GS-, WS- en pulsstroommeting.

    eienaardigheid

    ◆ Ooplus Hall ASIC-beginsel;
    ◆ Primêre kant en sekondêre kant isolasie;
    ◆ Lae kragverbruik;
    ◆ Wye reeks;
    ◆ Geen invoegverlies
    ◆ Grondstof voldoen aan UL 94-V0

    Toepassing

    ◆ Motorbeheerder
    ◆ Ononderbroke kragtoevoer (UPS)
    ◆ Statiese omskakelaar aangedryf deur GS-motor
    ◆ Skakelkragtoevoer (SMPS)
    ◆ Kragtoevoer vir sweismasjien

    Modellys

    Produkmodel
    Modelnommer Gegradeerde insetstroom IPN(A) Meetbereik IPM (A)

    HS78-600A/900A-C

    600/900

    ±600/±900

    S78-600A/900A-C Parameterlys

    Parameter

    simbool

    eenheid Minimum waarde tipiese waarde Maksimum waarde opmerking
    1; 2; 3 Elektriese spesifikasies van die kanaal
    Primêre kant gegradeerde stroom

    IPN

    'n

    -

    600

    -

     
    Primêre stroommetingsbereik

    IPM

    'n

    -600

    -

    600  
    Toevoerspanning

    VC

    In

    4.75 5.0 5.25  
    Uitsetspanning

    VOUT

    In

    VOUT=(VC/5)·(2.5+Gth·IPN) @ VC=5V
    Nul uitsetspanning

    VQOV

    In

    2.48 2.5 2.52 @VC=5V en IP=0A
    Teoretiese wins

    Gth

    mV/A

    -

    3.33

    -

     
    Huidige verbruik

    IK

    m.a.

    -

    60

    70

    @VC=5V
    Laaiweerstand

    RL

    10

    -

    onbeperk @VOUT na GND
    Laaikapasitansie

    C2

    nF

    -

    -

    2.2  
    Kragfilterkapasitansie

    C1

    µF

    -

    -

    -

     
    4; 5; 6 Elektriese spesifikasies van die kanaal
    Primêre kant gegradeerde stroom

    IPN

    'n

    -

    900

    -

     
    Primêre stroommetingsbereik

    IPM

    'n

    -900

    -

    900  
    Toevoerspanning

    VC

    In

    4.75 5.0 5.25  
    Uitsetspanning

    VOUT

    In

    VOUT=(VC/5)·(2.5+Gth·IPN) @ VC=5V
    Nul uitsetspanning

    VQOV

    In

    2.48 2.5 2.52 @VC=5V en IP=0A
    Teoretiese wins

    Gth

    mV/A

    -

    2.22

    -

     
    Huidige verbruik

    IK

    m.a.

    -

    60

    70

    @VC=5V
    Laaiweerstand

    RL

    10

    -

    onbeperk @VOUT na GND
    Laaikapasitansie

    C2

    nF

    -

    -

    2.2  
    Kragfilterkapasitansie

    C1

    µF

    -

    -

    -

    Prestasieparameter
    Winsfout

    Ja

    %

    -

    ±2

    -

    @TA=25℃
    Temperatuurdrywing van winsfout

    TCG

    %/℃

    -0.03

    ±0.01

    0.03 @TA -40℃~125℃
    Nul fout

    VLIEG

    mV

    -

    ±20

    -

    @VC=5V en IP=0A
    Nul fout van temperatuurdrywing

    TCVOE

    mV/℃

    -0.08

    ±0.01

    0.08 @TA -40℃~125℃
    Magnetiese verrekeningspanning

    VAN DIE

    mV

    -4

    -

    4

    @TA=25℃, VC=5V
    Nie-lineêre fout

    HEL

    % van IPN

    -0.5

    -

    0.5 Nul gratis VOE
    Reaksietyd

    tr

    µs

    3

    6

    10  
    Bandwydte (-3dB)

    Swart-wit

    kHz

    30

    -

    -

     
    Huidige volgelinge

    di/dt

    'n/Ons  

    100

       
    Uitsetgeraas

    Een bl.

    mV

    -

    -

    10  
    Universele parameter
    Bedryfsomgewingstemperatuur

    T'n

    -40….+125

     
    Bergingsomgewingstemperatuur

    TS

    -40….+125

     
    gewig

    m

    g

    -

    Aandag

    (1) Die uitsetspanning Uout, verrekeningspanning UQOV, sensitiwiteit Gth is heeltemal eweredig aan die kragtoevoer Vc;

    (2) Die frekwensie van die stroom wat gemeet moet word, moet beperk word tot die sensorfrekwensieband, anders sal dit oorverhitting van die magnetiese kern en skyfie veroorsaak;

    (3) Die verkeerde bedradingsmetode kan die sensor beskadig;

    Isolasie-eienskappe

    Parameter

    simbool

    eenheid

    Numeriese waarde

    opmerking
    AC-isolasieweerstandspanningstoets RMS @ 50Hz, 1min

    IND

    KV

    2.5

     
    Impulsweerstandspanning 1.2/50uS

    JOU

    KV

    5

     
    Behuisingsmateriaal

    -

    -

    UL94-V0

    PPS+GF40

    Relatiewe kruipweerstandsindeks

    KTI

    In

    -

     
    Kruipafstand

    dCP

    mm

    25

     
    Elektriese speling

    dCI

    mm

    20

    Maksimum limiet

    Parameter

    simbool

    eenheid

    Numeriese waarde
    Toevoerspanning

    InC

    In

    8

    Deurlopende uitsetstroom

    Ekuit

    m.a.

    -

    Elektrostatiese ontlading - Kontakontlading

    InESD

    KV

    4

    Meganiese Dimensies

    produkbeskrywing1

    Aandag

    Sensors moet voldoen aan IEC61010-1-standaarde. Sensors moet geïnstalleer word in elektroniese of elektriese toerusting wat voldoen aan toepassingsstandaarde en veiligheidsvereistes in ooreenstemming met die gebruiksaanwysings.
    • Pasop. Pasop vir skokke.
    • produkbeskrywing07
    • produkbeskrywing08
    Wanneer die sensor in werking is, kan sommige dele aan gevaarlike spannings blootgestel word (bv. primêre rail, kragtoevoer), en die verwaarlosing hiervan sal lei tot skade en ernstige gevare. Die sensor is 'n ingeboude toestel, en die geleidende deel daarvan moet gewaarborg word om nie deur die buitewêreld aangeraak te word na installasie nie. Beskermende omhulsel of afskerming kan bygevoeg word indien nodig. Die hoofkragtoevoer moet ontkoppel kan word.

    Leave Your Message